Trad-Lighting Photo Gallery

RLOD#52 (2020.11.13) Late-1950s Janse Lichtreclame 10-76133

The lamp shown here is representative of the very first fluorescent tubes made in the Netherlands. Produced by Janse Lichtreclame in the late 1950s under a Philips license, the model #10-76133 was made for the Electrical Engineering department of the then newly founded Technische Hogeschool Eindhoven (THE, now TU/e) in order to demonstrate the effect of strong electric fields on gases at low pressure. The lamp has several interesting features, such as a non-Penning neon-argon mix buffer designed for an efficient lamp operation over a wide temperature range, a coating of manganese-activated cadmium borate phosphor which results in a warm pinkish-white light color, and cold tubular electrodes closed by mica discs, with the front one made with a central hole to let the discharge through. This primitive hollow cathode is the first one developed at Philips in the mid-1920s for their electric discharge lamps of the positive-column type, later used during the 1930s in the company’s HTL200 high-voltage fluorescent tube whose overall design and geometry are similar to those of the present lamp (different dimensions though).


Keywords: Lamps

RLOD#52 (2020.11.13) Late-1950s Janse Lichtreclame 10-76133


The lamp shown here is representative of the very first fluorescent tubes made in the Netherlands. Produced by Janse Lichtreclame in the late 1950s under a Philips license, the model #10-76133 was made for the Electrical Engineering department of the then newly founded Technische Hogeschool Eindhoven (THE, now TU/e) in order to demonstrate the effect of strong electric fields on gases at low pressure. The lamp has several interesting features, such as a non-Penning neon-argon mix buffer designed for an efficient lamp operation over a wide temperature range, a coating of manganese-activated cadmium borate phosphor which results in a warm pinkish-white light color, and cold tubular electrodes closed by mica discs, with the front one made with a central hole to let the discharge through. This primitive hollow cathode is the first one developed at Philips in the mid-1920s for their electric discharge lamps of the positive-column type, later used during the 1930s in the company’s HTL200 high-voltage fluorescent tube whose overall design and geometry are similar to those of the present lamp (different dimensions though).

xenon~0.jpg alvin-book.jpg 2020-11-13_Janse_Lichtreclame_10-76133.jpg DSC_2299m.jpg 2020-09-27_Philips_FNF_50W.jpg
File information
Filename:2020-11-13_Janse_Lichtreclame_10-76133.jpg
Album name:Max / Random lamp of the day
Keywords:Lamps
Filesize:221 KiB
Date added:27 Oct 2026
Dimensions:750L x 115W mm
Displayed:40 times
URL:https://trad-lighting.net/gallery/displayimage.php?pid=1435
Favourites:Add to Favourites
Lamp/Fixture Information
Manufacturer:Janse Lichtreclame (Philips license)
Model Reference:10-76133
Lamp
Lamp Type:Mercury fluorescent low pressure, high-voltage type
Filament/Radiator Type:Nonthermal discharge in argon, neon, and mercury vapor, and fluorescence (manganese-activated cadmium borate)
Base:Screw lugs
Shape/Finish:Tubular fluorescent
Service Life:c. 100 kh
Burning Position:Universal
Electrical
Wattage:10.8 W
Voltage:474 V
Current:25 mA
Physical/Production
Factory Location:Eindhoven, the Netherlands
Fabrication Date:Late 1950s
Application/Use:Demonstration

Comment 1 to 13 of 13
Page: 1

Drew   [Tue 27 Oct 2026 at 19:37]
Very very cool I've never heard of these! From the looks of it it's pretty much just a neon sign tube, though I can't tell the diameter. What is that dark stuff surrounding the area where the phosphor starts? I wonder what it's efficiency is
Max   [Tue 27 Oct 2026 at 21:19]
The HTL-type of fluorescent tube is indeed not well known as its use in general lighting was very brief - spanning typically from the mid 1920s to the late 1930s. This is indeed related to the neon sign tube, the same kind of hollow cathode is used. As a matter of fact, Philips's HTL200 was derived from George Claude's neon and mercury sign tubes (France), whose technology was licensed to Philips when the Dutch began researching and developing their first positive-column gas discharge tubes in November 1924.

As for the efficacy of this tube, the data published by Philips in 1939 relative to its HTL200 indicate a power consumption of 58.5 W for a 2000 lm output for each tube, which corresponds to a 34 lm/W efficacy. Now, I haven't measured the exact luminous characteristics of the present #10-76133 tube, but I think its efficacy should be in the same ballpark given the more efficient operation of the mercury discharge at low current, compensated by the less efficacious red-emitting phosphor. Precise measurements will have to be done in order to answer that question properly though.

The "dark stuff" near where the phosphor coating starts is just black paint that was applied to block off the bluish (uncorrected) light from the mercury discharge. If you're referring to the darker trace visible along the phosphor-coated tube, that's just some excess fluorescent material that accumulated there when the tube was coated (which was done horizontally). Interestingly, this feature is intentional as it acts as a light reflector that increases the source luminance in the direction opposite to the electrode locations, a characteristic and a design which was patented. In its application the electrodes of the HTL200 where in the upward position while light was directed mostly downward. In essence, the first Dutch fluorescent tube was of a reflective kind!
Sammi   [Tue 27 Oct 2026 at 23:51]
Another wonderful picture.! Love Mind Blown
Max   [Wed 28 Oct 2026 at 03:12]
Thank you, Sammi. I hope you like the description as well, pictures are only half the story.
Drew   [Wed 28 Oct 2026 at 13:15]
Ahh okay interesting that does make sense, I suppose it's a similar concept to the black paint used on neon signs. I didn't even notice the uneven phosphor but that is so interesting that it was intentional. 34 lm/W is decent for the time I suppose, I think that's decently better than some low wattage HPMV lamps but I forget. Did these have dedicated ballasts or were they just meant to run in series on a neon sign transformer?
Ria   [Wed 28 Oct 2026 at 19:06]
Again, another amazing picture (and description..!) from our Max. I really must get around to posting more, it's been rather hectic here over the past few weeks and things show no sign of letting up Rolling Eyes
AgentHalogen_87   [Wed 28 Oct 2026 at 22:17]
Interesting lamp there! I like how the gas discharge peeks out by the cathodes. Does the black paint hide a rough edge of the phosphor coating, or just to hide most of the uncoated ends?
Max   [Thu 29 Oct 2026 at 07:12]
That's definitely not your usual fluorescent tube. As far as I can tell, the black paint covers the transition between two tubes, which where initially two separate parts: the phosphored tube and the clear one containing the electrode. The edge between the two parts is quite clean.

Ria - Thanks a lot! Please find/make some time to post more, you have a nice collection and I'd certainly like to see more of it here.

Drew - Those lamps (i.e., the HTL200) were meant to be run with several units in series, connected to a dedicated high-voltage transformer. In their December 1939 publication (Schouwstra and Zecher, Philips Technical Review) they point to installations where 9 lamps are connected end-to-end for a total luminous tube length of 18 meters for each transformer. This approach to the HTL system operation was meant to mitigate the relatively high losses from the transformer ballast. The overall system efficacy was 30 lm/W, which compared favorably to incandescent lamps (13.5 lm/W), the reference for the intended application, i.e., interior lighting.
Sammi   [Thu 29 Oct 2026 at 13:26]
Max, I love the descriptions as well. Love
very detailed, and a history lesson as well. Cool
Max   [Fri 30 Oct 2026 at 07:16]
Glad you like this, it's always good to know that it benefits a readership who still has a sense of curiosity and is not there just for the pretty pictures or because of some shared personality/mental disorders ;P
Sammi   [Fri 30 Oct 2026 at 23:41]
What do you mean by mental disorder.? Wonder Sad
Max   [Fri 30 Oct 2026 at 23:43]
You've never been to LG? That's actually a recurring topic there...
Sammi   [Fri 30 Oct 2026 at 23:58]
All right Fairy Nuff, we like to think we're here for a shared love of quality lighting. Bulb Man
The less said about LG the better.

Comment 1 to 13 of 13
Page: 1